Noyafa NF-268 Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
Your excellent helper in cable test!
5
3.5 Check breakage location of non-energized wires (as below)
Connect a broken wires with the two clips, push the key to “scan,
Keep the probe close to wire, it means normal if beep” emits. Then
move the probe along the wire, the point is breakage when no “beep
comes out.
Note:
1) clip one core with red clamp, keep the black one free.
2)turn the volume to degree 6-8 when tracing cable.
3)Clip one core to tested.
3.6 Network cable mapping
3.6.1) If the tested cable is in good connection, No.1-8 &G leds will
be on and blink in circulation.
3.6.2) If No. 2 & No.3 cables are broken, the No.2 led of emitter and
receiver wont be on. The others blink normally.
3.6.3) If No. 2 & No.3 cables are shorted, the No.2 & 3 Leds of receiver
wont be.
No.1-8 leds of emitter works normally.